These data were obtained by ASTM D-461 Test Methods, ASTM D-2475 Standards, and NTA Wool Felt Specifications.
F-11 Specification and Uses
Commercial Standard Grade 9R2
SAE Number F-11
NTA Number 18R2
GENERAL PROPERTIES
Wool Content (fiber basis) min. 87%
Density (1") 8.48 lbs/sq yd
Standard Thickness Range 1/8" to 1"
Standard Width 72"
Color Gray
PHYSICAL PROPERTIES
Specific Gravity 18%
Therm. Cond. (70F) 0.24 btu/hr/sq. ft./°F/in.
Thermal Expansion 0
Air Perm (1/16") 75-150 cfm/sq ft/0.5"H2O
Liquid Absorption
by volume
>375% by weight (1.0 sp gr)
88
Capillarity (wicking height, 575 SSU, 70F) 2.50
Coef of Friction (1) 0.37
Vibration Absorption (2)
static load bearing cap/unit area
dynamic stress endurance

Low
High - Medium
Noise Reduction Coef (1") 0.64
MECHANICAL PROPERTIES
Tensile Strength (min) 200 psi
Elongation (100 psi) 35%
Mullen Bursting Strength (1/8") 60 psi
Split Resistance (min) 6 lb/2" width
Hardness Range 15-25 Shore A
Compressibility (10% defl) 4 psi
Recovery (within 1 min after 10% defl) 99%
Abrasion Resistance (3) Fair
CHEMICAL AND ENVIRONMENTAL PROPERTIES
Effect of Sunlight and Oxidation None
Solvent Resistance and Stability in Oil Excellent
Acid Resistance, dilute
concentration
Excellent
fair-good
Alkali Resistance, dilute
concentration
Fair
Low
Temperature Range -80 to +200 °F
TYPICAL USES
Dryer drum seals, impregnated packing, insoles, insulation; oil, dust and mud shields.